CL100
CL100 Cellular Inlet Louvers are used in a variety of new and retrofit applications, including air inlets for both package and field-erected counterflow towers. They improve airflow into the cooling tower, keep out debris, eliminate water splash-out – which can cause icing, near-site water damage, and costly water and water treatment chemical loss, – restrict the amount of sunlight into the cooling tower to impede algae growth, reduce noise from the tower, and improve the tower's appearance.
BENEFITS
Inlet Louvers Specifications
Products | Sheet Thickness inches | Sheet Spacing inches | Dry Weight lbs/ft2 | Depth inches | Width inches | Length inches |
---|---|---|---|---|---|---|
CL80 - 2.5" | 0.010 - Corrugated sheet 0.025 - Wave sheet | 0.8 | 0.76 | 2.5 | 16 | 12, 24, 36, 48, 60, 72, 96, 120 |
CL80 - 3.2" | 0.010 - Corrugated sheet 0.025 - Wave sheet | 0.8 | 0.97 | 3.2 | 16 | 12, 24, 36, 48, 60, 72, 96, 120 |
CL80 - 2.5" Framed Panel | 0.010 - Corrugated sheet 0.025 - Wave sheet | N/A | 1.23 | 2.88 | 96 Max. (With max. panel area of 24 sq. ft.) | 96 Max. (With max. panel area of 24 sq. ft.) |
CL80 - 3.2" Framed Panel | 0.010 - Corrugated sheet 0.025 - Wave sheet | N/A | 1.50 | 3.57 | 96 Max. (With max. panel area of 24 sq. ft.) | 96 Max. (With max. panel area of 24 sq. ft.) |
CL100 | 0.015 | 1 | 1.00 | 2.5 | 12 | 12, 24, 36, 48, 60, 72, 96, 120 |
CL100 Framed Panel | 0.015 | N/A | 1.47 | 2.88 | 96 Max. (With max. panel area of 24 sq. ft.) | 96 Max. (With max. panel area of 24 sq. ft.) |
ML25SS | 0.018 | N/A | 4.0 | 2.5 | 12.77 | 24-120 (in 1 inch increments) |
ML32SS | 0.018 | N/A | 3.9 | 3.2 | 13.01 | 24-120 (in 1 inch increments) |
DLP/C 065 | 0.20 | 0.91 | 0.92 | 2.48 | 27.56 Max. | 94.49 Max. |
DLPWE 065 | 0.20 | 0.94 | 1.02 | 2.48 | 27.56 Max. | 94.49 Max. |
Products | Sheet Thickness mm | Sheet Spacing mm | Dry Weight kg/m2 | Depth mm | Width mm | Length mm |
---|---|---|---|---|---|---|
CL80 - 2.5" | 0.25 - Corrugated sheet 0.64 - Wave sheet | 20 | 3.72 | 63.5 | 406 | 305, 610, 914, 1219, 1524, 1829, 2438, 3048 |
CL80 - 3.2" | 0.25 - Corrugated sheet 0.64 - Wave sheet | 20 | 4.75 | 81.3 | 406 | 305, 610, 914, 1219, 1524, 1829, 2438, 3048 |
CL80 - 2.5" Framed Panel | 0.25 - Corrugated sheet 0.64 - Wave sheet | N/A | 6.02 | 73.2 | 2438 Max. | 2438 Max. |
CL80 - 3.2" Framed Panel | 0.25 - Corrugated sheet 0.64 - Wave sheet | N/A | 7.34 | 90.7 | 2438 Max. | 2438 Max. |
CL100 | 0.38 | 25.4 | 4.89 | 63.5 | 305 | 305, 610, 914, 1219, 1524, 1829, 2438, 3048 |
CL100 Framed Panel | 0.38 | N/A | 7.19 | 73.2 | 2438 Max. | 2438 Max. |
ML25SS | 0.46 | N/A | 19.47 | 63.5 | 324.4 | 610-3048 (in 254 mm increments) |
ML32SS | 0.46 | N/A | 18.97 | 81.3 | 330.6 | 610-3048 (in 254 mm increments) |
DLP/C 065 | 0.50 | 23 | 4.50 | 63.0 | 700 Max. | 2400 Max. |
DLPWE 065 | 0.50 | 24 | 5.00 | 63.0 | 700 Max. | 2400 Max. |
Complementary Inlet Louver Components
BL105 LOUVER BRACKET
This bracket is a rigid PVC extrusion used for mounting inlet louvers to ensure easy, secure installation. It is compatible with standard 4.2-inch corrugated louver blades.
FRAMED PANEL
The optional CL80 and CL100 assembly frames are made of extruded PVC and enable easy installation and cleaning access.