Three large cooling towers from a power plant emit white steam against a clear blue sky. The gray towers, adorned with red-and-white patterned tops, stand prominently in the image.

CL100

CL100 Cellular Inlet Louvers are used in a variety of new and retrofit applications, including air inlets for both package and field-erected counterflow towers. They improve airflow into the cooling tower, keep out debris, eliminate water splash-out – which can cause icing, near-site water damage, and costly water and water treatment chemical loss, – restrict the amount of sunlight into the cooling tower to impede algae growth, reduce noise from the tower, and improve the tower's appearance.

Inlet Louvers Specifications

English Metric
ProductsSheet Thickness
inches
Sheet Spacing
inches
Dry Weight
lbs/ft2
Depth
inches
Width
inches
Length
inches
CL80 - 2.5"
0.010 - Corrugated sheet
0.025 - Wave sheet
0.8
0.76
2.5
16
12, 24, 36, 48, 60, 72, 96, 120
CL80 - 3.2"
0.010 - Corrugated sheet
0.025 - Wave sheet
0.8
0.97
3.2
16
12, 24, 36, 48, 60, 72, 96, 120
CL80 - 2.5" Framed Panel
0.010 - Corrugated sheet
0.025 - Wave sheet
N/A
1.23
2.88
96 Max.
(With max. panel area of 24 sq. ft.)
96 Max.
(With max. panel area of 24 sq. ft.)
CL80 - 3.2" Framed Panel
0.010 - Corrugated sheet
0.025 - Wave sheet
N/A
1.50
3.57
96 Max.
(With max. panel area of 24 sq. ft.)
96 Max.
(With max. panel area of 24 sq. ft.)
CL100
0.015
1
1.00
2.5
12
12, 24, 36, 48, 60, 72, 96, 120
CL100 Framed Panel
0.015
N/A
1.47
2.88
96 Max.
(With max. panel area of 24 sq. ft.)
96 Max.
(With max. panel area of 24 sq. ft.)
ML25SS
0.018
N/A
4.0
2.5
12.77
24-120 (in 1 inch increments)
ML32SS
0.018
N/A
3.9
3.2
13.01
24-120 (in 1 inch increments)
DLP/C 065
0.20
0.91
0.92
2.48
27.56 Max.
94.49 Max.
DLPWE 065
0.20
0.94
1.02
2.48
27.56 Max.
94.49 Max.
ProductsSheet Thickness
mm
Sheet Spacing
mm
Dry Weight
kg/m2
Depth
mm
Width
mm
Length
mm
CL80 - 2.5"
0.25 - Corrugated sheet
0.64 - Wave sheet
20
3.72
63.5
406
305, 610, 914, 1219, 1524, 1829, 2438, 3048
CL80 - 3.2"
0.25 - Corrugated sheet
0.64 - Wave sheet
20
4.75
81.3
406
305, 610, 914, 1219, 1524, 1829, 2438, 3048
CL80 - 2.5" Framed Panel
0.25 - Corrugated sheet
0.64 - Wave sheet
N/A
6.02
73.2
2438 Max.
2438 Max.
CL80 - 3.2" Framed Panel
0.25 - Corrugated sheet
0.64 - Wave sheet
N/A
7.34
90.7
2438 Max.
2438 Max.
CL100
0.38
25.4
4.89
63.5
305
305, 610, 914, 1219, 1524, 1829, 2438, 3048
CL100 Framed Panel
0.38
N/A
7.19
73.2
2438 Max.
2438 Max.
ML25SS
0.46
N/A
19.47
63.5
324.4
610-3048 (in 254 mm increments)
ML32SS
0.46
N/A
18.97
81.3
330.6
610-3048 (in 254 mm increments)
DLP/C 065
0.50
23
4.50
63.0
700 Max.
2400 Max.
DLPWE 065
0.50
24
5.00
63.0
700 Max.
2400 Max.

Complementary Inlet Louver Components

BL105 LOUVER BRACKET
FRAMED PANEL
BL105 LOUVER BRACKET

This bracket is a rigid PVC extrusion used for mounting inlet louvers to ensure easy, secure installation. It is compatible with standard 4.2-inch corrugated louver blades.

FRAMED PANEL

The optional CL80 and CL100 assembly frames are made of extruded PVC and enable easy installation and cleaning access.

an image showcasing the CL80 cooling tower component louver an image showcasing the CL80 cooling tower component louver

Inlet Louvers for Cooling Towers Products

Abstract image featuring a minimalist design of white and light gray geometric shapes. The background has a subtle gradient, creating a clean and modern aesthetic.
Start A Conversation

A Partner You Can Rely On

Complete the form below to learn about the benefits of partnering with Brentwood to maximize your tower’s performance.













    CL100
    X